DESCRIPTION:
The CAN PC/104 Plus card is a high-performance solution for connecting two
High-Speed CAN networks with a PC/104 Plus (Based on the PCI Bus Architecture) system. This card is equipped with the SJA1000 CAN controller and the 82C251 driver. Up to four cards can be stacked within one system.
The position of the card in the stack is set with jumpers.
A version of the
card based on the standard ISA bus version of PC/104, the
CAN PC/104 card is also
available
Connection to the
CAN bus is via a 10-pin upright connector. A cable from the 10 pin
connector to a slot bracket with a 9-pin D-SUB connector (pin assignment in
accordance with standard recommendation CiA DS 102-1) is provided. The
opto-decoupled version (optional) guarantees galvanic isolation of up to 500
volts between the PC/104-Plus and the CAN using an integrated DC/DC converter
and optocoupler.
The PCAN-PC/104-Plus card includes software for Windows® and sample
source-code for do-it-yourself programming. Driver sources for LINUX are also
available.
The CAN PC/104 Plus card includes software for Windows® and sample sources for in-house programming. LINUX drivers are also available.
Peak Systems Cross Reference: IPEH-002094.
FEATURES:
Baud rate settings up to 1 Mbit/s
1 or 2 Channel (optional) versions available
500V Opto Isolation available (optional)
120-pin connection for the PCI bus
Up to four cards can be used in one system
Electrical adjustment to slot position via jumper
Philips CAN controller SJA10000 with 16 MHz frequency
CAN transceiver 82C251
Hardware reset possible via software
CAN bus connection in accordance with CiA DS 102-1
DOCUMENTATION, DRIVER & SOFTWARE:
SPECIFICATIONS:
|
PART NUMBERS |
|
|
1 Channel |
GC-CAN-PC104PL-1
(IPEH-002094) |
|
2 Channel |
GC-CAN-PC104PL-2
(IPEH-002095) |
|
1 Channel
w/Isolation |
GC-CAN-PC104PL-1-ISO
(IPEH-002096) |
|
2 Channel
w/Isolation |
GC-CAN-PC104PL-2-ISO
(IPEH-002097) |
|
PC/104 INTERFACE |
|
|
PC Interface |
PC/104-Plus (version 2.0), 32 bit PCI-bus,
for 3.3V and 5V systems |
|
I/O and IRQ |
automatically assigned via "plug n
play" |
|
Power Consumption |
GC-CAN-PC104PL-1 max. 150
mA GC-CAN-PC104PL-2 max 280 mA GC-CAN-PC104PL-1-ISO max 260 mA
GC-CAN-PC104PL-2-ISO max 490 mA |
|
CANbus |
|
|
CAN Interface |
ISO 11898-2, complies with CiA-recommendation
DS 102 |
|
CAN Specification |
2.0A (Standard format) and 2.0B
(extended format) |
|
CAN Controller |
max. 2 Philips SJA1000 |
|
CAN Transceiver |
max. 2 Philips PCA82C251 |
|
Isolation |
500VDC (optional) GC-CAN-PC104PL-x-ISO |
|
Connector |
10-pin Upright Connector |
|
Pinout |
C.I.A. DS-102 (CAN_H = 7, CAN_L = 2, CAN_GND = 3) |
|
CAN Baud Rate |
max. 1 MBit/s |
|
ENVIRONMENTAL |
|
|
Operating Temperature |
-40...85 °C |
|
Storage Temperature |
-40...125 °C |
|
Rel. Humidity |
15%...90%, not condensing |
|
Dimensions |
96 x 91 x 15 mm (L x W x H) (Approx) |
|
Weight |
max. 52 g |
|
EMC Directive |
EN 55024:2003-10 EN 55022:2003-09
EN 61000-4-3 EN 61000-4-6 EN 61326 (EN 55011) EC directive 89/336/EEC |
|
Certifications |
CE Mark |
|
RoHS |
Yes |
|
SOFTWARE |
|
|
Driver |
Windows® 2000, XP and Vista; Linux |
|
Tools |
PCAN-View for Windows® |
MPN: IPEH-002094